Center air-condition
product
 
 
 
 
   
 

 

 

 
 
 

Nameㄩ Single-leaf gravity fire damper
TypeㄩFD-1A
MaterialㄩPlate steel
Specificationㄩ
According to design requirement.
Descriptionㄩ
1. The damper shall be installed in the ventilating and air conditioning system and it can also be installed in the fireproof wall or ground platform. 2. The leaf flap keeps open as usual, when current temperature exceed fusible links melting degree, it will cut-off and the damper shut off automatically under the flap*s gravity to prevent the high temperature flows and the flame*s spread.
Markㄩ
Type 每 W ℅ H

 

 
 

Nameㄩ Round gravity fire damper
TypeㄩFD-1R
MaterialㄩCarbon steel
Specificationㄩ
According to design requirement
Descriptionㄩ
1. The damper shall be installed in the ventilating and air conditioning system and it can also be installed in the fireproof wall or ground platform. 2. The leaf flap keeps open as usual, when current temperature exceed fusible links melting degree, it will cut-off and the damper shut off automatically under the flap*s gravity to prevent the high temperature flows and the flame*s spread.
Markㄩ
Type 每 朴d

 

 
 
Nameㄩ Rectangle fire damper
TypeㄩFFH-2
MaterialㄩCarbon steel
Specificationㄩ
According to design requirement
Descriptionㄩ
1. The damper shall be installed in the ventilating and air conditioning system and it can also be installed in the fireproof wall or ground platform. 2. The leaf flap keeps open as usual, when current temperature exceed fusible links melting degree, it will cut-off and the damper shut off automatically .It can also be opened manually and return manually. 3. The damper can adjust volume to five grades, export electrical signal and have lock device.
Markㄩ
Type 每 W ℅ H
 
 
 

Nameㄩ Rectangle fire-smoke volume damper
TypeㄩFFH-3
MaterialㄩCarbon steel
Specificationㄩ
According to design requirement
Descriptionㄩ
1. The damper shall be installed in the ventilating and air conditioning system and it can also be installed in the fireproof wall or ground platform. 2. The blade flap keeps open as usual, When current temperature exceed fusible links melting degree, it will cut-off and the damper shut off automatically. It can also be opened manually and return manually. 3. The damper can adjust volume to five grades, export electrical signal and have lock device.
Markㄩ
Type 每 W ℅ H

 
 
 

Nameㄩ Round fire volume damper
TypeㄩFFH-5R
MaterialㄩCarbon steel
Specificationㄩ
According to design requirement
Descriptionㄩ
1. The damper shall be installed in the ventilating and air conditioning system and it can also be installed in the fireproof wall or ground platform. 2. The blade flap keeps open as usual, When current temperature exceed fusible links melting degree, it will cut-off and the damper shut off automatically. It can also be opened manually and return manually. 3. The damper can adjust volume to five grades, export electrical signal and have lock device.
Markㄩ
Type 每 朴d

 
 
 

Nameㄩ Round joint fire damper
TypeㄩFFH-9
MaterialㄩCarbon steel
Specificationㄩ
According to design requirement
Descriptionㄩ
1. The damper shall be installed in the ventilating and air conditioning system and it can also be installed in the fireproof wall or ground platform. 2. The blade flap keeps open as usual, When current temperature exceed fusible links melting degree, it will cut-off and the damper shut off automatically. It can also be opened manually and return manually. 3. The damper can adjust volume to five grades, export electrical signal and have lock device.
Markㄩ
Type 每 朴d

 
 
 

Nameㄩ Rectangle smoke exhaust damper
TypeㄩFPY-1
MaterialㄩCarbon steel
Specificationㄩ
According to design requirement
Descriptionㄩ
1. The damper shall be installed in the ventilating and air conditioning system and it can also be installed in the fireproof wall or ground platform. 2. The blade flap keeps open as usual, When current temperature exceed fusible links melting degree, it will cut-off and the damper shut off automatically. It can also be opened manually and return manually. 3. The damper can adjust volume to five grades, export electrical signal and have lock device.
Markㄩ
Type 每 W ℅ H

 
 
 

NameㄩBoarded smoke exhaust damper
TypeㄩPYK-1
MaterialㄩCarbon steel
Specificationㄩ
According to design requirement
Descriptionㄩ
1. The damper shall be installed in the ventilating and air conditioning system and it can also be installed in the fireproof wall or ground platform. 2. The blade flap keeps open as usual, When current temperature exceed fusible links melting degree, it will cut-off and the damper shut off automatically. It can also be opened manually and return manually. 3. The damper can adjust volume to five grades, export electrical signal and have lock device. 4. Be used as decorated.
Markㄩ
Type 每 W ℅ H

 
 
 
Nameㄩ Horizontal multi-leaf exhaust/dispatch outlet
TypeㄩPYK-4AW
MaterialㄩCarbon steel, aluminum alloy
Specificationㄩ
According to design requirement
Descriptionㄩ
1. The damper shall be installed in the ventilating and air conditioning system and it can also be installed in the fireproof wall or ground platform. 2. The blade flap keeps open as usual, When current temperature exceed fusible links melting degree, it will cut-off and the damper shut off automatically. It can also be opened manually and return manually. 3. The damper can adjust volume to five grades, export electrical signal and have lock device. 4. Be used as decorated.
Markㄩ
Type 每 W ℅ H
 
 
 

Nameㄩ Electric multi-leaf volume damper
TypeㄩVCD-1M
MaterialㄩCarbon steel
Specificationㄩ
According to design requirement
Descriptionㄩ
1. The damper shall be installed in the ventilating and air conditioning systemㄛit can be controlled by the angle of the leaf to adjust the volume. 2. Motor operates the angle of the blade through the connecting rod device.
Markㄩ
Type 每 W ℅ H

 
 
 
Nameㄩ Rectangle duct check damper
TypeㄩNRD-1
MaterialㄩGalvanized steel, aluminum alloy
Specificationㄩ
According to design requirement
Descriptionㄩ
1. The check damper shall be installed in the ventilating and air conditioning system. When the fan runs, the blades let the air pass. When the fan stops, the blades shut to prevent the airflow from reversing. 2. The direction of airflow should be consistent with the demand of the check damper.
Markㄩ
Type 每 W ℅ H
 
 
 
Nameㄩ Round volume damper
TypeㄩCDD
MaterialㄩGalvanized steel
Specificationㄩ
According to design requirement
Descriptionㄩ
1. The volume damper shall be installed in the ventilating and air conditioning system. 2. It can be controlled by the angle of the blade to adjust the volume.
Markㄩ
Type 每 朴d
 
 
 
Nameㄩ Access door
TypeㄩAD
MaterialㄩGalvanized steel
Specificationㄩ
According to design requirement
Descriptionㄩ
1. The door should be assembled on the side of the duct near the damper to provide convenience check.
Markㄩ
Type 每 W ℅ H
 
 
 
Nameㄩ Boarded automatically exhaust damper
TypeㄩYYF
MaterialㄩGalvanized steel, aluminum alloy
Specificationㄩ
According to the design requirement.
Descriptionㄩ
1. Be used to relieve air pressure automatically without energy in air conditioning and cleaning room. 2. It can be installed on the outside wall and connect with the inside varieties diffusers.
Markㄩ
Type 每 W ℅ H
 
 
 